Skip to content
PT SCBI

Overview · Quality

Quality Parameters of Shisha Charcoal: Ash, Moisture, Volatile Matter, Fixed Carbon, Calorific Value and Burn Time

This hub belongs to the quality section and is written for the quality or purchasing manager who compares shisha charcoal, the hookah charcoal or hookah coals of US and Canadian buyers, on its numbers. It lists the six parameters a specification is read on, how each one is obtained and where this factory's measured values are published. Each parameter has a page of its own.

Written by
Henry Sinaga
Reviewed by
Dimas Setyawan,
Updated
Reading time
5 min read
Coconut shell charcoal briquettes are classified under HS subheading 4402.20, charcoal of shells or nuts.

Quick answer

Which quality parameters describe coconut shell charcoal briquettes, and how does this factory measure them?

Coconut shell charcoal briquettes are judged on ash, moisture, volatile matter and fixed carbon; this factory's grades are set by ash alone, measured as received. The newest laboratory report on file, issued November 4, 2026, states moisture, ash, volatile matter and fixed carbon. Calorific value is not on it, and burn time is timed on a bench rather than in a laboratory.

1. Six parameters, four on the laboratory report

Four parameters come from the laboratory report, one would need a calorimeter, and one is timed on a bench.

Definition

charcoal specification

A charcoal specification, for coconut shell charcoal briquettes, is the set of measured parameters and limits a shipment is held to: laboratory results such as moisture, ash, volatile matter and fixed carbon, each with its method and basis, and physical properties such as size and strength.

The six quality parameters of coconut shell charcoal briquettes, how each is obtained and where it sits at this factory; the newest laboratory report on file was issued November 4, 2026, values as received; laboratory conditions as set by ASTM D1762-84 (2021).
ParameterWhat it measuresHow it is obtainedAt this factory
Ash content The mineral residue left when a sample burns completelyLaboratory: furnace at 750 °CSets the grade; newest report 1.64% as received
Moisture content The water in the sampleLaboratory: oven at 105 °C2% at most when a batch leaves the oven; newest report 3.21% as received
Volatile matter The part given off as gas when the sample is heated without airLaboratory: furnace at 950 °CIntake limit 14% or less on shell charcoal; newest report 12.33% as received
Fixed carbon What is left once moisture, volatile matter and ash are taken outCalculated: 100 minus the other threeIntake limit 82% or more on shell charcoal; newest report 82.82% as received
Calorific value The heat released when the sample burns completelyLaboratory: bomb calorimeterNot on the laboratory report on file
Burn time How long a piece stays lit and gives heatBench test, not a laboratory result3 pieces timed on an electric coil; no figure published

Each one has its own page: ash content, moisture content, volatile matter, fixed carbon, calorific value and burn time and heat.

How facts on this page are confirmed is set out in the editorial and review policy.

2. Which parameter sets the grade

Ash alone sets the grade at this factory, and the other three results are reported beside it.

The rule on file reads: ash alone sets the grade; moisture, volatile matter and fixed carbon are reported on the COA. Each range is read on the figure as received (wet basis), and a value exactly on the line between two ranges is sold as the lower grade.

The ranges are Platinum 1.6–1.9%, Super Premium 1.9–2.3% and Premium 2.3–2.5%. A shisha charcoal grade is this factory's own band, so the names do not carry over to another factory's limits: see how the parameters combine into a grade.

Note

Where the other limits sit

  • At intake, on shell charcoal. Moisture below 12%, fixed carbon 82% or more and volatile matter 14% or less.
  • At the oven, on every load. Moisture of 2% at most, measured with a moisture meter on every oven load.
  • On the laboratory report. No limit: moisture, volatile matter and fixed carbon are reported as measured.

3. The method and basis behind every figure

A laboratory figure means little without its method and its basis, and both are on every report.

The reports on file are issued by Carsurin Tbk (Semarang laboratory, Central Java). The factory's practice is a COA from the laboratory for each order. The register states the method as follows: Carsurin Tbk, Semarang laboratory (KAN accreditation LP-415-IDN for ISO/IEC 17025:2017, as printed on its reports), tests moisture, ash and volatile matter by ASTM D1762-84 (2021), sections 7.2, 7.4 and 7.3, and calculates fixed carbon (method MWI.01.63.LC).

Test conditions of ASTM D1762-84 (2021), the method named on this factory's laboratory report, for each result on the report.
ResultPart of the methodCondition
Moisture Section 7.2Dried in an oven at 105 °C for 2 hours
Volatile matter Section 7.3Heated in a muffle furnace at 950 °C
Ash Section 7.4Burned in a muffle furnace at 750 °C for 6 hours
Fixed carbon Not part of the methodCalculated by the laboratory by difference
Every laboratory figure on this site names its method and basis, as printed on the report that ships with each sample.

ASTM now lists the same designation as D1762-84 (2026); the reports on file name the 2021 edition. Each result is stated on a reporting basis, and the register copies the as-received figures. On the newest report they add up to 100.00%, because fixed carbon is the remainder. How to read one report field by field is in how to read our COA.

4. Where the measured values are published

Measured values go to registers, one row per report or check, and only confirmed rows are shown.

Laboratory results go to the batch COA register: the batches behind every figure on this page. It holds one confirmed report so far, and results from further shipments are added as they are tested.

  • Moisture at the oven. Measured with a moisture meter on every oven load; the readings are not published.
  • Size. Measured with a digital caliper on 20 pieces, 4 times a day, for the size-deviation log.
  • Strength. A drop test on lit pieces, 350 per oven load, for the drop-strength log.
In-line readings such as the moisture of each oven load stay at the factory; laboratory results are published in the register.

Neither log has confirmed rows yet. Why one report can differ from the next is on why batches vary. Your own test of a sample, a sample test, is set out in the sample test protocol.

Questions buyers ask

Are the laboratory results measured on the finished briquettes or on the shell charcoal?
On the finished briquettes: the laboratory tests a sample drawn from an export shipment. The shell charcoal is checked by the factory at intake against its own limits for moisture, fixed carbon and volatile matter, and those checks are not laboratory reports.
Do you publish limits for moisture, volatile matter and fixed carbon?
Not per grade: ash alone sets the grade, and the other three are reported on the COA. The factory's own limits sit elsewhere: moisture below 12%, fixed carbon 82% or more and volatile matter 14% or less for incoming shell charcoal, and moisture of 2% at most when a batch leaves the oven.

Sources

  1. ASTM D1762-84(2021), Standard Test Method for Chemical Analysis of Wood Charcoal (the edition named on the laboratory report) (opens in new tab), ASTM International — accessed
  2. ASTM D1762-84(2026), the current listing of the same test method (opens in new tab), ASTM International — accessed

Test before you commit a container

Samples ship with the batch COA; third-party inspection on request.