Quick answer
Which quality parameters describe coconut shell charcoal briquettes, and how does this factory measure them?
Coconut shell charcoal briquettes are judged on ash, moisture, volatile matter and fixed carbon; this factory's grades are set by ash alone, measured as received. The newest laboratory report on file, issued November 4, 2026, states moisture, ash, volatile matter and fixed carbon. Calorific value is not on it, and burn time is timed on a bench rather than in a laboratory.
In this section
-
Ash Content of Shisha Charcoal: The Range of Each Grade, Our Measured Value and What Ash Color Shows
Ash sets this factory's grade, from 1.6–1.9% for Platinum to 2.3–2.5% for Premium, measured as received on the laboratory report of each shipment.
-
Moisture Content of Shisha Charcoal: At the Oven, on the Laboratory Report and on Arrival
Briquettes leave the ovens at 2% moisture at most, checked with a meter on every oven load; the laboratory report states moisture as received.
-
Volatile Matter in Shisha Charcoal: The Intake Limit, Our Measured Value and Smoke at Ignition
Volatile matter is the share that leaves as gas when charcoal is heated; incoming shell charcoal is accepted at 14% or less.
-
Fixed Carbon in Shisha Charcoal: Calculated by Difference, the Intake Limit and Our Measured Value
Fixed carbon is calculated by difference, 100 minus moisture, ash and volatile matter; incoming shell charcoal is accepted at 82% or more.
-
Calorific Value of Shisha Charcoal: Units, Gross and Net, the Moisture Penalty, and What Is on File
Calorific value is not on the laboratory report on file; it is measured in kcal per kg with a bomb calorimeter, and moisture lowers it.
-
Burn Time and Heat of Shisha Charcoal: What They Depend On, Our Bench Method and What We Do Not Guarantee
Burn time depends on piece size, density and heating; this factory times 3 pieces on an electric coil, recording time to light and burn time.
1. Six parameters, four on the laboratory report
Four parameters come from the laboratory report, one would need a calorimeter, and one is timed on a bench.
Definition
charcoal specification
A charcoal specification, for coconut shell charcoal briquettes, is the set of measured parameters and limits a shipment is held to: laboratory results such as moisture, ash, volatile matter and fixed carbon, each with its method and basis, and physical properties such as size and strength.
| Parameter | What it measures | How it is obtained | At this factory |
|---|---|---|---|
| Ash content | The mineral residue left when a sample burns completely | Laboratory: furnace at 750 °C | Sets the grade; newest report 1.64% as received |
| Moisture content | The water in the sample | Laboratory: oven at 105 °C | 2% at most when a batch leaves the oven; newest report 3.21% as received |
| Volatile matter | The part given off as gas when the sample is heated without air | Laboratory: furnace at 950 °C | Intake limit 14% or less on shell charcoal; newest report 12.33% as received |
| Fixed carbon | What is left once moisture, volatile matter and ash are taken out | Calculated: 100 minus the other three | Intake limit 82% or more on shell charcoal; newest report 82.82% as received |
| Calorific value | The heat released when the sample burns completely | Laboratory: bomb calorimeter | Not on the laboratory report on file |
| Burn time | How long a piece stays lit and gives heat | Bench test, not a laboratory result | 3 pieces timed on an electric coil; no figure published |
Each one has its own page: ash content, moisture content, volatile matter, fixed carbon, calorific value and burn time and heat.
How facts on this page are confirmed is set out in the editorial and review policy.
2. Which parameter sets the grade
Ash alone sets the grade at this factory, and the other three results are reported beside it.
The rule on file reads: ash alone sets the grade; moisture, volatile matter and fixed carbon are reported on the COA. Each range is read on the figure as received (wet basis), and a value exactly on the line between two ranges is sold as the lower grade.
The ranges are Platinum 1.6–1.9%, Super Premium 1.9–2.3% and Premium 2.3–2.5%. A shisha charcoal grade is this factory's own band, so the names do not carry over to another factory's limits: see how the parameters combine into a grade.
Note
Where the other limits sit
- At intake, on shell charcoal. Moisture below 12%, fixed carbon 82% or more and volatile matter 14% or less.
- At the oven, on every load. Moisture of 2% at most, measured with a moisture meter on every oven load.
- On the laboratory report. No limit: moisture, volatile matter and fixed carbon are reported as measured.
3. The method and basis behind every figure
A laboratory figure means little without its method and its basis, and both are on every report.
The reports on file are issued by Carsurin Tbk (Semarang laboratory, Central Java). The factory's practice is a COA from the laboratory for each order. The register states the method as follows: Carsurin Tbk, Semarang laboratory (KAN accreditation LP-415-IDN for ISO/IEC 17025:2017, as printed on its reports), tests moisture, ash and volatile matter by ASTM D1762-84 (2021), sections 7.2, 7.4 and 7.3, and calculates fixed carbon (method MWI.01.63.LC).
| Result | Part of the method | Condition |
|---|---|---|
| Moisture | Section 7.2 | Dried in an oven at 105 °C for 2 hours |
| Volatile matter | Section 7.3 | Heated in a muffle furnace at 950 °C |
| Ash | Section 7.4 | Burned in a muffle furnace at 750 °C for 6 hours |
| Fixed carbon | Not part of the method | Calculated by the laboratory by difference |
ASTM now lists the same designation as D1762-84 (2026); the reports on file name the 2021 edition. Each result is stated on a reporting basis, and the register copies the as-received figures. On the newest report they add up to 100.00%, because fixed carbon is the remainder. How to read one report field by field is in how to read our COA.
4. Where the measured values are published
Measured values go to registers, one row per report or check, and only confirmed rows are shown.
Laboratory results go to the batch COA register: the batches behind every figure on this page. It holds one confirmed report so far, and results from further shipments are added as they are tested.
- Moisture at the oven. Measured with a moisture meter on every oven load; the readings are not published.
- Size. Measured with a digital caliper on 20 pieces, 4 times a day, for the size-deviation log.
- Strength. A drop test on lit pieces, 350 per oven load, for the drop-strength log.
Neither log has confirmed rows yet. Why one report can differ from the next is on why batches vary. Your own test of a sample, a sample test, is set out in the sample test protocol.
Questions buyers ask
Are the laboratory results measured on the finished briquettes or on the shell charcoal?
Do you publish limits for moisture, volatile matter and fixed carbon?
Sources
- ASTM D1762-84(2021), Standard Test Method for Chemical Analysis of Wood Charcoal (the edition named on the laboratory report) (opens in new tab), ASTM International — accessed
- ASTM D1762-84(2026), the current listing of the same test method (opens in new tab), ASTM International — accessed