Skip to content
PT SCBI

Record · Quality

Batch COA Register: Measured Ash, Moisture, Volatile Matter and Fixed Carbon per Export Shipment

This register belongs to the quality section and lists the laboratory results behind each export shipment of shisha charcoal, the hookah charcoal or hookah coals of US and Canadian buyers, measured against the shisha charcoal grade bands. It is written for a quality or purchasing manager checking measured values before a sample or a container. Every row is copied from a laboratory's report with its report date, and nothing in it is typed from memory.

Written by
Henry Sinaga
Reviewed by
Dimas Setyawan,
Updated
Reading time
3 min read

Quick answer

What did the last batches of this factory's shisha charcoal actually measure?

The register lists the laboratory-measured ash, moisture, volatile matter and fixed carbon of each export shipment, by report date, newest first. Each row is one laboratory report on coconut shell charcoal briquettes from Carsurin Tbk (Semarang laboratory, Central Java), with values as received. Compare the ash with the grade bands, check the report date against your window, and ask which shipment your container will come from.

Batch COA register: 1 confirmed record from 2026-11-04 to 2026-11-04. One row per laboratory report, each on one export shipment.
Date BatchAsh (%)Moisture (%)Volatile matter (%)Fixed carbon (%)Laboratory
not stated; booking number masked1.643.2112.3382.82Carsurin Tbk, Semarang

Method: Carsurin Tbk, Semarang laboratory (KAN accreditation LP-415-IDN for ISO/IEC 17025:2017, as printed on its reports), tests moisture, ash and volatile matter by ASTM D1762-84 (2021), sections 7.2, 7.4 and 7.3, and calculates fixed carbon (method MWI.01.63.LC); the table copies the values as received (wet basis), the first column of each report.

Last updated 2026-11-04 · re-checked at least every 90 days · next due by 2027-02-02.

1. What a row in this register is

One row is one laboratory report on one export shipment: the report date, four measured values and the laboratory.

Definition

batch COA

A batch COA (certificate of analysis) is a laboratory report on a sample drawn from one batch or shipment of charcoal, stating its measured moisture, ash, volatile matter and fixed carbon, and sometimes its calorific value, with the test method and the report date.

The factory's practice is a COA from the laboratory for each order. The reports on file are issued by Carsurin Tbk (Semarang laboratory, Central Java).

The table copies the values as received, the wet-basis column of each report; a report that also prints dry-basis values keeps them in the full report. Where a report names no batch number, the row says so, and the booking number of the shipment is masked in every row.

Each field is explained in how to read our COA and what one COA cannot tell you, and the grade ranges these batches are measured against are on the grades page.

2. The register

The register sits at the top of this page, newest report first, with the method it is kept by and the date it was last checked, like the other published records.

  • Date. The issue date of the report.
  • Batch. The batch number the report names, or a note that it names none.
  • Ash, moisture, volatile matter, fixed carbon. Percentages as received, as the laboratory reports them.
  • Laboratory. The laboratory that issued the report.

To see the full report behind a row, ask the export desk for it by its report date; the copy is sent with the details of the shipment masked. How rows are sourced, checked and corrected is set out in the editorial and review policy.

3. Reading a row against your specification

A row is useful when it is read against your own specification, in three checks.

  1. Step 1

    Check the ash against the grade band

    On the grades page. Find the band of the grade you buy and check the row's ash against it. In the newest row, dated 2026-11-04, ash is 1.64% as received, inside the 1.6–1.9% band of Platinum.

  2. Step 2

    Check the report date

    Against your window. A row is one shipment on one date. Decide how recent a report must be for your purchase, and read only the rows inside that window.

  3. Step 3

    Ask which shipment is yours

    Before the deposit. The newest row is not the value your container will have. Ask the export desk which production your container will be drawn from; under the factory's practice of a COA from the laboratory for each order, your container's own report is issued for it.

How to read each value, and what a single report cannot tell you, is covered in how to read our COA.

4. What this register cannot show

One row is one sample of one shipment, so the register cannot show how far the values vary inside that shipment, or between your approved sample and the bulk.

Note

Where the other checks are

No buyer's name, container number or booking number appears in the register.

Questions buyers ask

Who issues the certificate of analysis, and how often?
Carsurin Tbk (Semarang laboratory, Central Java) issues the certificates on file, and the factory's practice is a COA from the laboratory for each order. Each certificate becomes one row here, dated by its report date, when the report arrives.
Can I get the full laboratory report behind a row?
Yes. Ask the export desk for the report behind a row by its report date. A copy is sent with the details of the shipment it belongs to masked, such as the booking number.
Why do values differ from batch to batch?
Shell charcoal arrives from more than one supplier and region, and carbonization is never perfectly uniform; the grade bands exist to bound that variation. A shipment whose ash sits inside its band is in grade. This register shows one value per shipment; the variation inside a shipment and between the approved sample and the bulk is covered by the retained samples and the sample-to-bulk chain.

Use the data before you order

Request a sample from current production and compare it with the latest rows.