Quick answer
How do I test a shisha charcoal sample so the result is comparable and useful?
A sample test is useful only when every candidate runs through one fixed setup and results sit on one record sheet beside the batch COA. This protocol runs seven steps on a 1 kg sample of coconut shell charcoal briquettes and records each field against the COA field or spec sheet line it is compared with. The approved sheet becomes the baseline for your first container.
1. What this protocol is for
A sample test is worth running only when its numbers can be compared — with another candidate, or with the documents the sample came with.
Definition
sample test
A sample test is a buyer-side evaluation of a charcoal sample that records lighting time, burn behavior, ash, smell, dimensions and breakage under one fixed setup so that candidates can be compared and the approved sample fixed.
The results have two uses. The first is choosing between candidates: samples from two or three suppliers, or two grades from one supplier, run through the same setup on the same day. The second is fixing the approved sample: the sheet you fill for the sample you approve records what the first container has to match. Both uses depend on one rule — every candidate goes through the same heat source, bowl, airflow and steps, written down before the first piece is lit.
Note
A bench test cannot measure laboratory values: moisture, ash, volatile matter and fixed carbon come from the batch COA, and calorific value needs a laboratory report that states it. One parcel also cannot show whether later batches will match it; that is the subject of the sample-to-bulk consistency page and the batch COA register.
2. Before you start: the parcel, the room, the equipment
Before the first bag is opened, copy four things from the parcel onto the sheet: the batch number on the bag label, the production date, the shape and size, and the grade.
The batch number is the key to the whole test: it ties every measurement on the sheet to one batch COA. What a shisha charcoal sample contains and which documents travel with it are set out on the samples page; if a document is missing, ask for it before testing rather than after.
Keep the bags sealed, dry and at room temperature until test day, and open each bag on the day it is tested: pieces take up moisture from humid air, and a bag opened a week early is no longer the sample that was sent. The equipment fits on one bench:
- a scale reading to 0.1 g;
- a caliper reading to 0.1 mm, or a steel rule for a rougher check;
- a stopwatch;
- an electric coil, or the gas burner your lounges use;
- one bowl and one heat-management device, the same for every candidate;
- tongs and a metal tray for the ash;
- a marked height of 1 m above a concrete floor for the drop check;
- the record sheet in section 5, one copy per candidate.
Caution
Burning charcoal releases carbon monoxide, a gas with no color and no smell. Run every test in a ventilated room or under extraction, never in a closed room, and keep the coil and the hot ash away from anything that can catch fire.
3. The fixed setup
Choose the heat source, the bowl and device, the airflow and the room once, write them in the setup block at the top of the sheet, and change nothing until the last candidate is finished.
| Setting | What to write down | Why it stays fixed |
|---|---|---|
| Heat source | Coil model and setting, or burner and flame setting | Ignition time depends on how much heat reaches the contact face |
| Bowl and heat-management device | Bowl type and device model | Burn duration and heat stability depend on how the device holds and vents heat |
| Airflow | Fan on or off, window open or closed, extraction on or off | Moving air speeds combustion and carries ash off the tray |
| Room | Temperature, and the day each bag was opened | Pieces take up moisture from humid air, which slows ignition |
Two settings in particular make results incomparable when they vary: flame contact and airflow. A gas flame heats a piece unevenly depending on the burner and the distance, and a fan or an open window speeds combustion and carries ash away, so the same charcoal can light faster and seem to leave less ash on one day than on the next. Start every candidate from a cold coil, let the same person run the steps, and test all candidates on the same day where you can.
4. The test, step by step
Run the seven steps in order on one candidate, write each result down as you go, and finish the sheet before the next bag is opened.
-
Step 1
Count and weigh the bag
Pieces per kilogram. Weigh the opened bag and count every piece in it. Divide the count by the mass in kilograms and write the result as pieces per kg; it is compared with the spec sheet line for your shape and size.
-
Step 2
Measure ten pieces
Three dimensions, one mass. Take ten pieces at random, not the ten that look best. Measure length, width and height of each with the caliper, weigh each piece, and mark every piece that falls outside the dimension band on the spec sheet.
-
Step 3
Drop the same ten pieces
One meter, onto concrete. Drop each measured piece once from 1 m onto a concrete floor. Count a piece as broken when it splits into two or more parts, and note chipped edges separately.
-
Step 4
Ignite three new pieces
Time to full glow. Weigh three unused pieces together and place them on the heat source at the setting in the setup block. Start the stopwatch when they touch the heat and stop it when every face is covered in grey ash and glowing. Note any smell or smoke while they light.
-
Step 5
Burn one bowl
To the end of useful heat. Move the three lit pieces to the bowl and the heat-management device and run them as your lounges would, until the heat is no longer useful. Record the duration in minutes, how many times the pieces had to be repositioned, and whether a piece was added.
-
Step 6
Collect and weigh the ash
A bench figure, not COA. Let the ash cool on the metal tray, weigh it, and divide by the starting mass of the three pieces to get ash as a percentage of burned mass. Note its color and whether the pieces kept their shape as ash.
-
Step 7
Complete the sheet
Before the next candidate. Fill every field before the next bag is opened. Let the coil cool to room temperature so the next candidate starts from the same cold setup.
Steps 1 to 3 check the pieces against the spec sheet, steps 4 to 6 record how the batch behaves in your setup, and step 7 keeps the candidates apart.
5. The record sheet
The record sheet has one row per measurement and one column that matters more than the others: what each figure is compared with.
| Field | How measured | Unit | Compared with |
|---|---|---|---|
| Batch number | Copied from the bag label | text | COA header |
| Pieces per kg | Piece count divided by bag mass | pieces/kg | Spec sheet line for the shape and size |
| Dimensions | Caliper, ten pieces, three dimensions each | mm | Spec sheet dimension band |
| Piece mass | Scale, the same ten pieces | g | Spec sheet line, where stated |
| Drop breakage | The same ten pieces, 1 m onto concrete | pieces broken of 10 | Spec sheet line, where stated; otherwise candidate to candidate |
| Ignition time | Three pieces on the heat source | minutes | Candidate to candidate only |
| Burn duration | One bowl | minutes | Candidate to candidate only |
| Heat stability | Repositionings during the bowl | count | Candidate to candidate only |
| Ash mass | Tray and scale | % of burned mass (bench) | Candidate to candidate only; not the COA ash field |
| Ash color and shape | Observation | note | Candidate to candidate only |
| Smell and smoke at ignition | Observation | note | Candidate to candidate only |
Every field points either to a document, the COA header or a spec sheet line, or to the other candidates. The table prints on one page: fill one copy per candidate with the setup block at the top, and keep the approved copy for the arrival check on your first container, where the dimension, mass and breakage rows are measured again on pieces taken from the cartons.
6. Reading your results against the COA
Read the sheet in two halves: the fields that can be checked against the documents, and the fields that only rank candidates.
Batch number, pieces per kg, dimensions, piece mass and, where the spec sheet states a line, drop breakage are compared with the spec sheet and the COA header. The COA fields your results are compared with are explained one by one, with the method each is measured by.
Ignition time, burn duration, heat stability, bench ash and smell are bench-only. They depend on your coil, bowl, device and room, so they rank candidates against each other and against what your lounges expect; they are never compared with a factory figure. A bench ash weight is not the COA ash percentage either: the laboratory heats a portion in a furnace by a stated method, while a bowl burn stops when the heat fades and loses ash to airflow.
| Aspect | Laboratory COA | Bench test |
|---|---|---|
| Method | A named test method, stated on the report | This protocol, in your setup |
| Sample | A prepared portion of the batch | Pieces as received in the parcel |
| Moisture basis | Stated on the report, for example dry or air-dried | As received, at room conditions |
| Level | One production batch | Individual pieces |
| Use | Compare with the spec sheet | Compare candidates |
Important
A result outside a spec sheet band is a disqualifier: the sample does not match its own documents, and it should not be approved until the difference is explained. A result that depends on your device, such as a longer ignition, a shorter bowl or a smell you dislike, is a note: it may rule a candidate out for your lounges, but it says nothing about whether the batch meets its specification.
7. After the test
Every test ends in one of three branches, and each one ends with the sheet in a file.
The sample you approve becomes the golden sample, so the sheet you filled for it is the written half of that reference. A sample you set aside is still useful: the field that failed tells the export desk which shisha charcoal grade, shape or size to send next.
-
Report the approved sample
Approved. Tell the export desk which bag you approved and send the completed sheet with its batch number, so your first order names the sample it has to match.
-
Name the field that failed
Not approved. Tell the export desk which field failed and by how much, so the next sample is a different shape, size or grade rather than the same one again.
-
Keep one sheet per candidate
Approved or not. File every sheet with its setup block. The approved sheet is the baseline for the arrival check on your first container; the others show why a candidate was set aside.
The arrival check on your first container
If no parcel has arrived yet, request the sample this protocol is written for and print the sheet before it lands.