Skip to content
PT SCBI

Overview

Shisha Charcoal Quality: What Is Checked, Against Which Limit, and Where Results Are Published

The quality section of charcoal.co.id is for buyers comparing a specification, and for repeat buyers checking the consistency of shisha charcoal, the hookah charcoal or hookah coals of US and Canadian buyers. It lists what is checked, the limit each check is held to and where the results are published. The limits are the factory's stated limits; measured results appear only once they are confirmed.

Written by
Henry Sinaga
Reviewed by
Dimas Setyawan,
Updated
Reading time
5 min read
A digital caliper reads to 0.01 mm; the size tolerance of a briquette is stated per side against its nominal dimension.

Quick answer

How does this factory check the quality of its shisha charcoal, and where can I see the results?

Quality rests on a stated ash range per grade, in-line checks and a retained sample of every batch; measured results are published only once confirmed. Five limits are on file for coconut shell charcoal briquettes: ash by grade, size tolerance, moisture after the oven, temperature at packing and weathering days. Registers with confirmed rows are linked below.

In this section

  1. Batch COA Register: Measured Ash, Moisture, Volatile Matter and Fixed Carbon per Export Shipment

    The register lists the laboratory-measured ash, moisture, volatile matter and fixed carbon of each export shipment, by report date, newest first.

  2. How to Read Our COA: The Fields of One Laboratory Report, and What One Report Cannot Tell You

    A COA from this factory reports what a sample of one export shipment measured, by which method and basis; it says nothing about other shipments.

  3. Quality Parameters of Shisha Charcoal: Ash, Moisture, Volatile Matter, Fixed Carbon, Calorific Value and Burn Time

    Coconut shell charcoal briquettes are judged on ash, moisture, volatile matter and fixed carbon; this factory's grades are set by ash alone, measured as received.

  4. Pieces per Kilogram and Net Weight: How Shisha Charcoal Is Counted, Weighed and Claimed

    The factory sells by net weight; the count per kg is a nominal figure set by the cube size, not a guarantee for each carton.

  5. From Sample to Container #5: How Your Approved Sample Is Held

    The approved sample is kept so reorders can be matched to it, and a sample of every batch is retained for 5 years.

  6. Sample Test Protocol for Shisha Charcoal: One Setup, One Record Sheet, Compared With the Batch COA

    A sample test is useful only when every candidate runs through one fixed setup and results sit on one record sheet beside the batch COA.

  7. Pre-Shipment Inspection of Shisha Charcoal: Briefing Your Inspector and Timing the Visit

    Buyers' third-party inspectors are welcome before shipment, the factory pays for the pre-shipment inspection, and an independent surveyor also inspects the load.

  8. Claims and Remedies: Reporting a Shortage or a Quality Problem After a Container Arrives

    A shortage is reported within 7 days and a quality problem within 14 days of arrival at your warehouse; the remedy is credit or discount.

  9. Why Shisha Charcoal Batches Vary: Four Sources in Our Process and the Checks That Catch Drift

    Batches vary with the shell charcoal bought, the mix, pressing and drying; the factory fails a batch on smell, high ash, cracks or uneven size.

  10. Shisha Charcoal Troubleshooting: Sparking, Smell at Ignition and Breakage, From Symptom to Claim

    Three symptoms are covered here (sparking, smell at ignition and breakage), each traced to its likely cause, the record to check and the claim route.

1. What is checked, and against which limit

The limits on file are few and stated, and each one has a register its measured values go to.

Definition

quality data

Quality data are the measurements a factory takes on its coconut shell charcoal briquettes — laboratory analysis, size checks, drop tests, burn tests, packing-day records — together with the frequency of each and where the results are published.

Limits this factory states for its coconut shell charcoal briquettes, and the register each measured value is published in; limits confirmed by the owner in November 2026, registers named even while they have no rows.
What is checkedLimit on fileMeasured values go to
Ash content By grade, from 1.6–1.9% (Platinum) to 2.3–2.5% (Premium)The batch COA register
Size Stated tolerance ±0.3 mm per sideThe size-deviation log
Moisture when a batch leaves the oven 2% at mostThe batch COA register
Temperature of the charcoal at packing 40 °C at mostThe stuffing and weathering records
Weathering before packing 14 daysThe stuffing and weathering records
Every piece, at packing Packed by the in-house team, who check every piece by handNone published

Size is measured with a digital caliper on 20 pieces, 4 times a day, and moisture at the oven is measured with a moisture meter on every oven load; the methods and frequency of the other in-house checks are not on file; the laboratory on file is Carsurin Tbk (Semarang laboratory, Central Java), and its reports name their test method. The checks in line order are on the quality checkpoints page, the ranges by grade on the grades and specifications page, and the container side under packing-day temperature and weathering records per container.

What each laboratory figure measures, and by which method, is on the quality parameters page; why one batch differs from the next is on why batches vary. How facts on these pages are confirmed is set out in the editorial and review policy.

2. The registers: batch COA, size, strength, stuffing

Each kind of result has its own register, and a register with no confirmed rows says so.

  • The batch COA register: confirmed rows published.
  • The size-deviation log: first rows being collected.
  • The drop-strength log: first rows being collected.
  • The stuffing and weathering records: first rows being collected.
  • The retained-sample log: first rows being collected.
A register row is one measurement of one batch, such as the measured side of a cube set against its nominal size.

Note

What one row cannot tell you

A row is one batch, one check or one container. It does not show variation inside a batch, and it never shows a buyer's name or a container number.

Measured laboratory values belong to the batch COA register, and each field of one report is explained in how to read our COA. The records hub lists every register we publish, with its cadence, as published records.

3. From sample to container: how your spec is held

A specification is held from the first sample to the container by four things the factory has confirmed.

  1. Step 1

    A sample with its batch COA

    Before any order. Free samples of 1–10 kg; the buyer pays the courier (DHL or EMS), and every sample ships with its batch certificate of analysis (COA).

    Samples

  2. Step 2

    Your own test

    On your own device. Test the sample the way your customers will use it, and write down what you see.

    The sample test protocol

  3. Step 3

    The approved sample, kept

    The reference for reorders. The approved sample is kept so reorders can be matched to the previous order.

    From sample to container

  4. Step 4

    A sample of every batch, retained

    Kept after shipment. On file: a sample of every batch, about 25 kg of each batch, kept for 5 years.

    Retained samples

The full path, with what is not on file yet, is on the page about the golden sample: from sample to container.

4. Your own checks: sample test, inspection, claims

Three checks are yours to run, and each has its own page.

A sample test on the buyer's own device records ignition, heat and ash under the conditions the charcoal will be used in.

When a delivery shows sparking, a smell at ignition or breakage, the troubleshooting guide traces the likely cause and the record to check before a claim.

Questions buyers ask

Who tests your charcoal, and how often?
The checks on file are the factory's own: intake limits for the shell charcoal, the moisture limit at the oven, the criteria that fail a batch, and a hand check of every piece at packing. Size is measured with a digital caliper on 20 pieces, 4 times a day; how often the other checks run is not on file. Laboratory testing is done by Carsurin Tbk (Semarang laboratory, Central Java), under the factory's practice of a COA from the laboratory for each order.
What does a quality register on this site show, and what does it not show?
A register shows confirmed rows by date: the measured values of one batch, one check or one container, with the method and the source. It does not show variation inside a batch, and it never shows a buyer's identity or a container number. A register with no confirmed rows says so.
How do I compare your numbers with my current supplier's COA?
Compare values measured by the same method and on the same basis, not grade names. This factory's grades are set by an ash range, so start with the ash figure on your supplier's COA and check whether it is stated on a wet or a dry basis. If the method or the basis differs, ask the laboratory that issued the COA for the equivalent before you compare.

Test before you commit a container

Samples ship with the batch COA; third-party inspection on request.