Quick answer
How do I read this factory's certificate of analysis, and what does one report prove?
A COA from this factory reports what a sample of one export shipment measured, by which method and basis; it says nothing about other shipments. Read the laboratory and the dates first, then the four results with their basis, and compare the ash of the coconut shell charcoal briquettes with the grade range on the same basis.
1. What one COA is
One COA is one laboratory report on one sample drawn from one export shipment, which this site calls a batch COA.
The reports on file are issued by Carsurin Tbk (Semarang laboratory, Central Java). The factory's practice is a COA from the laboratory for each order, so the shipment of each order gets its own report.
A report you see before ordering belongs to an earlier shipment. Every report on file is one row in the batch COA register, dated by its issue date.
2. The fields, in reading order
The report reads top to bottom in eight fields, and each field has one thing to check.
| Field | What it shows | What to check |
|---|---|---|
| Issuer | The laboratory, Carsurin Tbk (Semarang laboratory, Central Java), with the accreditation line it prints. | The laboratory named is the one you ask to confirm the report. |
| Report number | The laboratory's own number for this report. | It lets the laboratory find the report (section 5). |
| Dates | Sampling, analysis and issue; the newest report on file was issued on 2026-11-04. | They run in that order. The register dates each row by the issue date. |
| Client | PT Shisha Charcoal Briquettes Indonesia | The report is in the factory's own name, not a trader's or another factory's. |
| Sample | What was sampled, and the shipment it was drawn from. | A copy sent to you has the shipment's booking number masked. |
| Results | Moisture, ash, volatile matter and fixed carbon, in percent. | Each figure carries its unit and its basis (section 3). |
| Methods | The test method behind each result. | Compare it with the method of any report you set beside it. |
| Signatory and stamp | The laboratory's signatory and its stamp. | Both are on the copy you receive. |
A copy of the full report behind any register row is available from the export desk, with the details of its shipment masked.
3. The four results, their basis and their method
Each result is a percentage of the sample's mass, and a figure means nothing without its basis.
Definition
reporting basis
The reporting basis of a laboratory result is the moisture state it refers to: as received (wet basis), with the sample's moisture included, or dry basis, with the moisture excluded.
| Result | As received (%) | What it measures |
|---|---|---|
| Moisture | 3.21 | Water in the sample, driven off by drying. |
| Ash | 1.64 | The mineral residue left after the sample burns completely. |
| Volatile matter | 12.33 | The part that leaves the sample as gas when it is heated without air. |
| Fixed carbon | 82.82 | The carbon left once moisture, volatile matter and ash are taken out; calculated, not weighed. |
Method, as the register states it: Carsurin Tbk, Semarang laboratory (KAN accreditation LP-415-IDN for ISO/IEC 17025:2017, as printed on its reports), tests moisture, ash and volatile matter by ASTM D1762-84 (2021), sections 7.2, 7.4 and 7.3, and calculates fixed carbon (method MWI.01.63.LC).
The four as-received figures add up to 100.00%, because fixed carbon is calculated from the other three, and the same check works on any report. The report also prints a dry-basis column, kept in the full report; its figures are higher than the as-received ones, because the moisture is left out.
Each result has a page of its own: moisture content, ash content, volatile matter and fixed carbon.
4. Reading a result against a grade
A result is read against a grade in four steps.
-
Step 1
Find the ash range of your grade
On the grades page. The ash ranges are Platinum 1.6–1.9%, Super Premium 1.9–2.3% and Premium 2.3–2.5%.
-
Step 2
Compare on one basis
Like with like. The grade ranges are read on the figure as received (wet basis), the figure the batch COA register copies, so compare a range with that column of the report and not with the dry one.
-
Step 3
Check the date and the shipment
One report, one shipment. A report belongs to the shipment its sample was drawn from; the newest report on file was issued on 2026-11-04. Read the report of the shipment you are buying.
-
Step 4
Read a value on a line
One rule. A value exactly on the line between two ranges is sold as the lower grade, the grade with the higher ash range.
The ranges, and what each grade is for, are on the grades page: the ash range of each grade. The newest report read against those ranges is in the batch COA register.
5. What one COA cannot tell you
One report shows what one sample measured; the other questions a buyer asks are answered elsewhere.
Note
What a COA does not show
- The next shipment. A report covers one sample of one shipment.
- Burn behavior. Burn time, ash color, smell and sparking are judged in a sample test, set out in the sample test protocol.
- Size, shape and breakage. A COA does not measure them; measured sizes belong to the size log.
- Variation inside a shipment and from sample to bulk. The golden sample and the retained sample cover it: why a single COA needs the retained sample behind it.
- The calorific value. The reports on file state four results, and the calorific value is not among them: how to read a calorific value.
- Whether the report is genuine. The report number and the laboratory's name let you ask the laboratory directly: how to verify the report with the laboratory.
The editorial policy sets out how a report is checked before its row is added.