Skip to content
PT SCBI

Guide · Quality

How to Read Our COA: The Fields of One Laboratory Report, and What One Report Cannot Tell You

This guide belongs to the quality section and reads the certificate of analysis (COA) of this factory's shisha charcoal, the hookah charcoal or hookah coals of US and Canadian buyers, field by field. It is written for a quality or purchasing manager with a report in hand. Every value shown is copied from the newest report in the batch COA register, and nothing is typed from memory.

Written by
Henry Sinaga
Reviewed by
Dimas Setyawan,
Updated
Reading time
4 min read
A 1 kg sample of shisha charcoal per shape and grade is enough for a burn test, a caliper check of ten pieces and a drop test of ten pieces.

Quick answer

How do I read this factory's certificate of analysis, and what does one report prove?

A COA from this factory reports what a sample of one export shipment measured, by which method and basis; it says nothing about other shipments. Read the laboratory and the dates first, then the four results with their basis, and compare the ash of the coconut shell charcoal briquettes with the grade range on the same basis.

1. What one COA is

One COA is one laboratory report on one sample drawn from one export shipment, which this site calls a batch COA.

The reports on file are issued by Carsurin Tbk (Semarang laboratory, Central Java). The factory's practice is a COA from the laboratory for each order, so the shipment of each order gets its own report.

A report you see before ordering belongs to an earlier shipment. Every report on file is one row in the batch COA register, dated by its issue date.

2. The fields, in reading order

The report reads top to bottom in eight fields, and each field has one thing to check.

The fields of a certificate of analysis on this factory's coconut shell charcoal briquettes, in the order they appear on the report; the laboratory and dates are those of the newest report in the batch COA register, issued 2026-11-04.
FieldWhat it showsWhat to check
Issuer The laboratory, Carsurin Tbk (Semarang laboratory, Central Java), with the accreditation line it prints.The laboratory named is the one you ask to confirm the report.
Report number The laboratory's own number for this report.It lets the laboratory find the report (section 5).
Dates Sampling, analysis and issue; the newest report on file was issued on 2026-11-04.They run in that order. The register dates each row by the issue date.
Client PT Shisha Charcoal Briquettes IndonesiaThe report is in the factory's own name, not a trader's or another factory's.
Sample What was sampled, and the shipment it was drawn from.A copy sent to you has the shipment's booking number masked.
Results Moisture, ash, volatile matter and fixed carbon, in percent.Each figure carries its unit and its basis (section 3).
Methods The test method behind each result.Compare it with the method of any report you set beside it.
Signatory and stamp The laboratory's signatory and its stamp.Both are on the copy you receive.

A copy of the full report behind any register row is available from the export desk, with the details of its shipment masked.

3. The four results, their basis and their method

Each result is a percentage of the sample's mass, and a figure means nothing without its basis.

Definition

reporting basis

The reporting basis of a laboratory result is the moisture state it refers to: as received (wet basis), with the sample's moisture included, or dry basis, with the moisture excluded.

Results of the newest laboratory report in the batch COA register, issued 2026-11-04, in percent of the sample as received; the method of each is named in the line below the table.
ResultAs received (%)What it measures
Moisture 3.21Water in the sample, driven off by drying.
Ash 1.64The mineral residue left after the sample burns completely.
Volatile matter 12.33The part that leaves the sample as gas when it is heated without air.
Fixed carbon 82.82The carbon left once moisture, volatile matter and ash are taken out; calculated, not weighed.

Method, as the register states it: Carsurin Tbk, Semarang laboratory (KAN accreditation LP-415-IDN for ISO/IEC 17025:2017, as printed on its reports), tests moisture, ash and volatile matter by ASTM D1762-84 (2021), sections 7.2, 7.4 and 7.3, and calculates fixed carbon (method MWI.01.63.LC).

The four as-received figures add up to 100.00%, because fixed carbon is calculated from the other three, and the same check works on any report. The report also prints a dry-basis column, kept in the full report; its figures are higher than the as-received ones, because the moisture is left out.

Each result has a page of its own: moisture content, ash content, volatile matter and fixed carbon.

4. Reading a result against a grade

A result is read against a grade in four steps.

A comparison holds only on the same terms: two samples on one card, or a laboratory figure and a grade range on one basis.
  1. Step 1

    Find the ash range of your grade

    On the grades page. The ash ranges are Platinum 1.6–1.9%, Super Premium 1.9–2.3% and Premium 2.3–2.5%.

  2. Step 2

    Compare on one basis

    Like with like. The grade ranges are read on the figure as received (wet basis), the figure the batch COA register copies, so compare a range with that column of the report and not with the dry one.

  3. Step 3

    Check the date and the shipment

    One report, one shipment. A report belongs to the shipment its sample was drawn from; the newest report on file was issued on 2026-11-04. Read the report of the shipment you are buying.

  4. Step 4

    Read a value on a line

    One rule. A value exactly on the line between two ranges is sold as the lower grade, the grade with the higher ash range.

The ranges, and what each grade is for, are on the grades page: the ash range of each grade. The newest report read against those ranges is in the batch COA register.

5. What one COA cannot tell you

One report shows what one sample measured; the other questions a buyer asks are answered elsewhere.

Piece size is a caliper measurement; it is not among the results a certificate of analysis states.

Note

What a COA does not show

  • The next shipment. A report covers one sample of one shipment.
  • Burn behavior. Burn time, ash color, smell and sparking are judged in a sample test, set out in the sample test protocol.
  • Size, shape and breakage. A COA does not measure them; measured sizes belong to the size log.
  • Variation inside a shipment and from sample to bulk. The golden sample and the retained sample cover it: why a single COA needs the retained sample behind it.
  • The calorific value. The reports on file state four results, and the calorific value is not among them: how to read a calorific value.
  • Whether the report is genuine. The report number and the laboratory's name let you ask the laboratory directly: how to verify the report with the laboratory.

The editorial policy sets out how a report is checked before its row is added.

Questions buyers ask

Is the COA I see now the report for my container?
No. Each report covers a sample of one export shipment, so a report you see before ordering belongs to an earlier shipment. The factory's practice is a COA from the laboratory for each order, so the shipment of your order gets its own report.
Why does the report show two columns of results?
The laboratory states each result as received, with the sample's moisture included, and on a dry basis, with the moisture excluded, so the dry figures are higher. The batch COA register copies the as-received column; the dry column stays in the full report.
Does a COA say how long the charcoal burns?
No. A COA states laboratory results such as ash, moisture and volatile matter. Burn time, ash color and smell are judged by burning pieces of the sample, as the sample test protocol sets out.

Test before you commit a container

Samples ship with the batch COA; third-party inspection on request.